Edit image action is unsuccessful
Apply the recommendations that pertain to your situation.
Possible cause and recommendationSymptom
The image is set to “Read Only”
You see Error getting image when
editing an image
1. Ensure that the image Protected setting shows “Read-Write.
2. Retry the Edit Image action.
Other image settings or the image itself are incorrect
1. Ensure that the image metadata is correct and that the image is valid. If
the image is not valid, you will need to recreate it.
2. Retry the Edit Image action.
If the error persists, download and check log files. From the Settings screen,
select ActionsDownload audit logs.
Image server storage configuration is unsuccessful
Apply the recommendations that pertain to your situation.
Possible cause and recommendationSymptom
Dedicated glance storage volume is not available for mounting
at startup
You see Error occurred during
image server storage
configuration
1. Ensure that there is a device named /dev/sdb and that it is accessible
to the appliance VM that was configured during initial installation.
2. Download and check log files for additional information. From the Settings
screen, select ActionsDownload audit logs.
If the error persists, contact your storage administrator.
Base folder of the ESX cluster shared datastore may contain files related to unused
images
Possible cause and recommendationSymptom
Files related to unused images are not cleared
To free space, manually delete the unused image files from the base folder
of the ESX cluster.
You see unused image files in the ESX
cluster shared datastore
Using the OpenStack Glance API to upload an image may not succeed when
CloudSystem Foundation is first installed
Possible cause and recommendationSymptom
CloudSystem Foundation is not fully up and running
When you upload an image using the
OpenStackGlance API, you see Failed
From the Actions menu on the CloudSystem Console Settings screen, select
“Reboot Foundation appliances.
to configure store correctly:
Store cinder could not be
Retry adding the image.
configured correctly. Reason:
Cinder storage requires a
context. Disabling add method
Troubleshooting images 165