HP 490455-421 Scheda Tecnica

Navigare online o scaricare Scheda Tecnica per Server HP 490455-421. HP ProLiant 160 G6 Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 55
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
The HP ProLiant DL160 G6 server is a high performance, low cost, ultra-dense, dual processor capable, 1U rack server for memory
intense High Performance Computing (HPC) environments, Web 2.0, hosting, and general large memory footprint server deployments.
Hot Plug SAS/SATA and Non-Hot Plug SATA Models
Front View:
Rear View:
1.
Access panel
1.
Power Supply Cable Socket
2.
System fans
2.
Video Port
3.
Two USB ports
3.
Serial Port
4.
Power on/off & system LEDs
4.
Rear USB ports (2)
5.
Optional 3
rd
and 4
th
3.5" Non-Hot plug SATA or hot plug
SAS/SATA hard drive bays
5.
One GbE LAN ports for shared NIC 2 (RJ-45)
6.
Optional DVD-RW or DVD-ROM drive
6.
Optional LO100i 10/100 Mbps LAN port for dedicated IPMI
management (RJ-45)
7.
Standard 1st and 2nd 3.5" Non-Hot plug SATA or hot plug
SAS/SATA hard drive bays (Small Form Factor drive cage not
shown here. See the Storage Section for orientation of eight
small form factor drive option)
7.
Low-Profile slot cover (not used in this model)
8.
Full-height PCI-Express x16
9.
UID - Rear Unit Identification LED
10.
One GbE LAN ports for NIC 1 (RJ-45)
8.
Eighteen DIMM slots : DDR3 Registered (RDIMM) or
Unbuffered (UDIMM) memory
9.
Expansion Slots:
Slot 1:Full-length/Full height x16 PCI-Express Gen2 slot, or
Slot 1: Half-length/Full height x16 PCI-Express Gen2 slot
and
Slot 2: Low Profile x4 PCI-Express Gen2 slot (accepts x8
cards, internal only)
10.
Six Core Intel® Xeon® 5600 ,Quad-Core Intel® Xeon® 5600 &
Quad-Core Intel® Xeon® 5500 series processors (supports up
to two)
11.
Power supply (500 Watts - standard, other PS options
available)
What's New
Support for SAS Hot Plug 2.5" Enterprise Mainstream Hard Drives
QuickSpecs
HP ProLiant DL160 Generation 6 (G6)
Overview
DA - 13247 Worldwide — Version 59 — September 24, 2012
Page 1
Vedere la pagina 0
1 2 3 4 5 6 ... 54 55

Sommario

Pagina 1 - QuickSpecs

The HP ProLiant DL160 G6 server is a high performance, low cost, ultra-dense, dual processor capable, 1U rack server for memoryintense High Performanc

Pagina 2

HP Simple ConfiguratorSCE is a guided self service tool to help sales and non technical people provide customers with initialconfigurations in 3 to 5

Pagina 3

Service and SupportHP Technology Services for Industry Standard Servers and BladeSystemCapitalizing on HP ProLiant server and HP BladeSystem capabilit

Pagina 4

Standard Care PackagePackage that maintains high level of server availabilityHP ProLiant Server Hardware InstallationProvides for the basic hardware i

Pagina 5

NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - FactoryIntegrat

Pagina 6

HP ProLiant DL160 G6X5650 2P 24GB-RP410/256 BBWC 8 SFF500W PS Server590162-xx1Processor(s)(2) Intel® Xeon® X5650 (2.66GHz/6-core/12MB/95W, DDR3-1333,

Pagina 7

NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations areordered, HP recomm

Pagina 8

Rack (1U), (1.75 in / 4.45 cm) Tool-less Fixed Rails NOTE: SFF CTO Chassis (P/N: 593352-B21) is not configurable with 130W Intel® Xeon®Processor Model

Pagina 9

HP MemoryRegistered DIMMs (RDIMMs)HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit500656-B21HP 4GB (1x4GB) Single Rank x4

Pagina 10

HP Storage ControllersNOTE: A minimum of one Smart Array Controller is ONLY required when purchasing HotPlug SFF CTO Chassis Model (P/N 593352-B21) in

Pagina 11

Step 3: Choose Additional Factory Integratable OptionsHP Insight SoftwareHP Insight Control for Linux HP IC-LX FIO Entitl 24x7 Supp 1 LicTC203AHP Stor

Pagina 12

NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - FactoryIntegrat

Pagina 13

NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the use ofan HP approved confi

Pagina 14

HP MemoryRegistered DIMMs (RDIMMs)HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Registered CAS-9 Memory Kit500656-B21HP 4GB (1x4GB) Single Rank x4

Pagina 15

HP 3TB 3G SATA 7.2K rpm LFF (3.5-inch) Midline 1yr Warranty Hard Drive628059-B21HP 2TB 3G SATA 7.2K rpm LFF (3.5-inch) Midline 1yr Warranty Hard Drive

Pagina 16

SAS Hot Plug (3.5") Enterprise (ENT) Drives HP 600GB 6G SAS 15K rpm LFF (3.5-inch) Dual Port Enterprise 3yr Warranty Hard Drive516828-B21HP 450GB

Pagina 17

HP NetworkingGigabit Ethernet Adapters HP NC112T PCI Express Gigabit Server Adapter503746-B21HP NC360T PCI-E Dual Port Gigabit Server Adapter412648-B2

Pagina 18

NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the use ofan HP approved confi

Pagina 19

and Japan should order the physical equivalent.NOTE: For additional license kits including electronic delivery options, please see theInsight Rapid De

Pagina 20

HP I/O AcceleratorOptionsSecond Generation Accelerators HP 365GB Multi Level Cell G2 PCIe ioDrive2 for ProLiant Servers673642-B21HP 785GB Multi Level

Pagina 21

HP Graphics OptionsHP Graphic Card Power Adapter KitNOTE: The Graphic Power Adapter Kit can support up to 150 Watts.NOTE: A full-length graphic card c

Pagina 22

NOTE: This part number can be used to purchase a single license or to order multiplelicenses with a single activation key. Customers will receive a li

Pagina 23

Cache MemoryOne of the followingdepending on Model12 MB Level 3 cache4MB Level 3 cacheChipsetIntel® 5520 ChipsetUpgradeabilityUpgradeable to two proce

Pagina 24

HP Tape BackupNOTE: For the complete range of tape drives, autoloaders, libraries and media see:http://www.hp.com/go/tape. For hardware and software c

Pagina 25

HP Storage OptionsFibre Channel HBA NOTE: The following is a list of all Fibre Channel Host Bus Adapters for Windows andLinux. For detailed compatibil

Pagina 26

HP Uninterruptible PowerSystemsHP Rack-mountable UPS R5000 Uninterruptible Power System (UPS) HP R5KVA 3U IEC309-32A High Voltage INTL Uninterruptible

Pagina 27

HP Power DistributionUnitsHP Monitored Power Distribution Unit: Full Rack Version HP 8.6kVA 24A Single Input Three Phase NA/JP Monitored Power Distrib

Pagina 28

NOTE: Please see the QuickSpecs for Technical Specifications and additionalinformation:http://h18000.www1.hp.com/products/quickspecs/13650_div/13650_d

Pagina 29

must allow 5,350 sq cm (830 square inches) of hole evenly distributed from top tobottom to permit adequate airflow (equivalent to the required 64 perc

Pagina 30

HP ProLiant DL160 G6 (all models)NOTE: Memory configurations listed do not apply to "Factory Integrated Models".Standard Memory4GB (1x4GB) ,

Pagina 31

DIMM slot/capacity/populated speed tableDIMM TypeRegistered DIMMS (RDIMMs)Unbuffered with ECCDIMMs (UDIMMs)DIMM RankSingleRank(1R)Dual Rank (2R)Quad R

Pagina 32

18 DIMM SLOTS (9 per CPU node) CPU1 CPU2 slot #population orderslot #population order Chnl 11G1GChnl 12D2D3A3A Chnl 24H4HChnl 25E5E6B6B

Pagina 33

CPU1 CPU2 slot #population orderslot #population order Chnl 11G; 8GB DIMM1G; emptyChnl 12D; 8GB DIMM2D; empty3A; 2GB DIMM3A; empty Chnl 24

Pagina 34

Storage ControllerNon-Hot Plug and ColdPlug SATA ModelsHP Smart Array B110i SATA RAIDNOTE: Embedded SATA controller support transfer rate up to 3Gb/sN

Pagina 35

CPU1 CPU2 slot #population orderslot #population order Chnl 11G; empty1G; emptyChnl 12D; 4GB DIMM2D; empty3A; 4GB DIMM3A; empty Chnl 24H;

Pagina 36

CPU1 CPU2 slot #population orderslot #population order Chnl 11G; empty1G; emptyChnl 12D; 4GB DIMM2D; 4GB DIMM3A; 4GB DIMM3A; 4GB DIMM Chnl

Pagina 37

Following are memory options available from HP:HP MemoryRegistered DIMMs (RDIMMs) HP 2GB (1x2GB) Dual Rank x8 PC3-10600 (DDR3-1333) Registered CAS-9

Pagina 38

1-4Four Non-hot plug SATA or four 3.5" Hot-plug SAS/SATAhard drive baysAOptional DVD-ROM, or DVD RW1-8Eight Hot-plug SATA/SAS hard drive baysAOpt

Pagina 39

SATA Hot Plug LFF (3.5-inch) Entry (ETY) Drives QuantitySupportedPositionSupportedController250GB 3G SATA 7.2KUp to 41-8HP Smart Array P212 Controller

Pagina 40

450GB 6G SAS 7.2K146GB 6G SAS 15K72GB 6G SAS 15KSAS Hot Plug LFF (3.5-inch) Enterprise (ENT) Drives QuantitySupportedPositionSupportedController600GB

Pagina 41

6G SAS Hot Plug Enterprise Mainstream Solid State Drives QuantitySupportedPositionSupportedController800GB 6G SAS MLC SSDSFF400GB 6G SAS MLC SSD SFF20

Pagina 42

3U Rack-Mount Kit HP SCSI Tape AutoloadersDAT 72x10 Autoloader1/8 G2 AutoloaderExternalHP SC11Xe Ultra320 Single Channel/ PCIe x4 SCSI Host Bus Adap

Pagina 43

HP 750W Common Slot Gold Hot Plug Factory Integrated Power Supply Kit with BackplanePart Number535683-B21 Option KitInput Voltage Range (Vrms)100 to 2

Pagina 44

HP 460W Common Slot Gold Hot Plug Factory Integrated Power Supply Kit with BackplanePart Number535684-B21 Option KitInput Voltage Range (Vrms)100 to 2

Pagina 45

InterfacesParallelNoneNetwork RJ-45(Ethernet)2 10/100/1000 NIC ports (plus 1 optional dedicated port for the HP ProLiantLights-Out 100i Remote Managem

Pagina 46

HP 460W Common Slot Platinum Hot Plug Power Supply Kit with BackplanePart Number605923-B21 Option KitInput Voltage Range (Vrms)100 to 240Frequency Ran

Pagina 47

Power ProLiant DL160 G6 Fully Configured115V/60Hz 220V/50HzFully Loaded System Input Wattage (W)448 445Fully Loaded System Input Current (A rms)3.83

Pagina 48

System UnitDimensions (H x W x D)(with bezel)1.70 x 17.64 x 26.85 in (4.32 x 44.80 x 68.20 cm)Weight(approximate)Maximum(all hard drives, powersupplie

Pagina 49

with a fan fault or above 30°C (86°F).Non-operating-30° to 60°C (-22° to 140°F). Maximum rate ofchange is 20°C/hr (36°F/hr).Relative Humidity(non-cond

Pagina 50

NC362i Integrated DualPort Gigabit ServerAdapterNetwork InterfaceIntegrated 10/100/1000BASE-T TransceiverCombines a triple-speed IEEE 802.3TM - Compli

Pagina 51

Environment-friendlyProducts and ApproachEnd-of-life Managementand RecyclingHewlett-Packard offers end-of-life HP product return, trade-in, and recycl

Pagina 52

Operating Systems andVirtualization SoftwareSupport for ProLiantServersMicrosoft Windows ServerOracle SolarisRed Hat Enterprise Linux (RHEL)SUSE Linux

Pagina 53

WarrantyThis product is covered by a global limited warranty and supported by HP Services and a worldwidenetwork of HP Authorized Channel Partners. Ha

Pagina 54

HP Insight managementsoftwareHP Insight Control forLinuxHP Insight Control for Linux, as a product option, delivers essential lifecyclemanagement that

Pagina 55

HP Insight Management Agents for Systems Insight Manager (SIM)IntegrationHP Systems Management HomepageArray Configuration Utility (ACU)Array Diagnost

Commenti su questo manuale

Nessun commento