HP StorageWorks 20 - Modular Smart Array Guida Utente Pagina 11

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 63
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 10
Component identification 11
SAS and SATA hard drive LEDs
Item Description
1 Fault/ID LED (amber/blue)
2 Online LED (green)
SAS and SATA hard drive LED combinations
NOTE: Predictive failure alerts can occur only when the storage
enclosure is connected to a Smart Array controller.
Online/Activity
LED (green)
Fault/UID LED
(amber/blue)
Interpretation
On, off, or flashing Alternating amber
and blue
The drive has failed, or a predictive failure alert has been
received for this drive; it also has been selected by a
management application.
On, off, or flashing Steadily blue The drive is operating normally, and it has been selected by a
management application.
On Amber, flashing
regularly (1 Hz)
A predictive failure alert has been received for this drive.
Replace the drive as soon as possible.
On Off The drive is online, but it is not active currently.
Vedere la pagina 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 62 63

Commenti su questo manuale

Nessun commento