Removal and replacement procedures 26
Hard drive blank
CAUTION: To prevent improper cooling and thermal damage, do not operate the server blade
or the enclosure unless all hard drive and device bays are populated with either a component
or a blank.
Remove the component as indicated.
To replace the blank, slide the blank into the bay until it locks into place.
Hard drive
To remove the component:
1. Determine the status of the hard drive from the hot-plug SAS hard drive LED combinations ("SAS and
SATA hard drive LED combinations" on page 56).
2. Back up all server data on the hard drive.