QuickSpecs
HP Integrity Superdome Servers 16- processor, 32-
HP Integrity Superdome Servers 16- processor, 32-HP Integrity Superdome Servers 16- processor, 32-
HP Integrity Superdome Servers 16- processor, 32-
processor, and 64- processor Systems
processor, and 64- processor Systemsprocessor, and 64- processor Systems
processor, and 64- processor Systems
Overview
DA - 11717 Worldwide — Version 35 — December 6, 2006
Page 1
Vedere la pagina 0
1 2 3 4 5 6 ... 81 82

Sommario

Pagina 1 - QuickSpecs

QuickSpecsHP Integrity Superdome Servers 16- processor, 32-HP Integrity Superdome Servers 16- processor, 32-HP Integrity Superdome Servers 16- proces

Pagina 2

Standard HardwareStandard HardwareStandard HardwareStandard HardwareFeaturesFeaturesFeaturesFeaturesRedundant Power suppliesRedundant FansFactory inte

Pagina 3

There are three basic building blocks in the Superdome system architecture: the cell, the crossbar backplane and the PCI-X basedI/O subsystem.Cabinets

Pagina 4

systems use the 1 GB, 2 GB or 4 GB DIMMs only)Voltage Regulator Modules (VRM)Data busesOptional link to 12 PCI X I/O slotsCrossbar BackplaneCrossbar B

Pagina 5

Core I/OCore I/OCore I/OCore I/O (required bysx1000 systems only,sx2000 systems do nothave a core I/O)The core I/O in Superdome provides the base set

Pagina 6

OpenVMS Core I/OOpenVMS Core I/OOpenVMS Core I/OOpenVMS Core I/O(A6865A)(A6865A)(A6865A)(A6865A)(sx1000 systemsonly, sx2000 systems donot have core I/

Pagina 7

Peripheral SupportPeripheral SupportPeripheral SupportPeripheral SupportAll peripherals qualified for use with Superdome and/or for use in a Rack Syst

Pagina 8

PartitionsPartitionsPartitionsPartitionsSuperdome can be configured with hardware partitions, (nPars). Given that Windows Server 2003, SuSESLES 9, Red

Pagina 9

Windows Server 2003,Windows Server 2003,Windows Server 2003,Windows Server 2003,Datacenter edition forDatacenter edition forDatacenter edition forData

Pagina 10

The table below highlights which processors can co-exist on a Superdome in separate hard partitions.PA 8600PA 8600PA 8600PA 8600 PA 8700PA 8700PA 8700

Pagina 11

Step #5: Some I/O cards may need to be added for that specific hard partition (Windows does notsupport the identical set of I/O cards that HP-UX 11i s

Pagina 12

At A GlanceAt A GlanceAt A GlanceAt A GlanceThe latest release of Superdome, HP Integrity Superdome supports the new and improved sx2000 chip set.The

Pagina 13

hard partition to that Integrity Superdome and continue the execution of the application while it iscertified.8) Why can't PA-8700+ processors be

Pagina 14

(HP-UX 11i v1) in a mixed configuration is going to require a PA-RISC Firmware update.NOTE:NOTE:NOTE:NOTE: HP-UX 11iV2 is the only HP-UX version suppo

Pagina 15

firmware andfirmware andfirmware andfirmware andmanagement toolsmanagement toolsmanagement toolsmanagement tools(sx1000 systems only)(sx1000 systems o

Pagina 16

Possible upgrades: If it is important to be able to use the Parmgr GUI on the PA HPUX 11i v1 you canupgrade HPUX to HWE 0412 and follow the process in

Pagina 17

WLM:WLM:WLM:WLM:WLM (workload manager) currently uses the Unix command "uname -i" to ensure that all the partitions itis managing are on the

Pagina 18

operation.NOTE:NOTE:NOTE:NOTE: Dynamic memory resilience is not supported when running Windows Server 2003,SUSE SLES 9,r Red Hat RHEL AS 3, or OpenVMS

Pagina 19

Multi-system HighMulti-system HighMulti-system HighMulti-system HighAvailabilityAvailabilityAvailabilityAvailabilityHP-UX 11i v2HP-UX 11i v2HP-UX 11i

Pagina 20

EMC CLARiiON FC4700EMC CLARiiON CX200/CX400/CX600EMC CLARiiON CX300/CX500/CX700EMC Symmetrix 8000 FamilyEMC DMX 800/1000/2000/3000HP has qualified and

Pagina 21

Below is the ordering information for Windows Server 2003 Datacenter Edition (for Itanium 2 based HP Integrity Superdome only).To order a system with

Pagina 22

Below is the ordering information for Windows Server 2003 Enterprise Edition (for Itanium 2 based HP Integrity Superdome only).NOTE: NOTE: NOTE: NOTE:

Pagina 23

Windows Server 2003,Windows Server 2003,Windows Server 2003,Windows Server 2003,Datacenter Edition orDatacenter Edition orDatacenter Edition orDatacen

Pagina 24

Network AdapterNetwork AdapterNetwork AdapterNetwork AdapterTeaming with WindowsTeaming with WindowsTeaming with WindowsTeaming with WindowsServer 200

Pagina 25

Service ProcessorService ProcessorService ProcessorService Processor (MP)The service processor (MP) utility hardware is an independent support system

Pagina 26

Support ManagementSupport ManagementSupport ManagementSupport ManagementStatioStatioStatioStation (SMS)The Support Management Station (SMS) runs the S

Pagina 27

These can each drive different solutions to the console access requirement.The considerations listed below apply to the design of provision of console

Pagina 28

Windows Server 2003Windows Server 2003Windows Server 2003Windows Server 2003For Windows Server 2003 customers desiring uninterrupted visibility to the

Pagina 29

SupportSupportSupportSupportThe following matrix describes the supported SMS and recommended console devices for allSuperdomes.SMS and Console Support

Pagina 30

Runs HP's proven highly effective JTAG scan diagnostic tools, which offer rapid fault resolution tothe failing wire.Console log storage and viewi

Pagina 31

Software RequirementsSoftware RequirementsSoftware RequirementsSoftware RequirementsAll SMS software is preloaded in the factory and delivered to the

Pagina 32

1.2.3.4.5.Mixed Superdome EnvironmentsMixed Superdome EnvironmentsMixed Superdome EnvironmentsMixed Superdome EnvironmentsSome important rules regardi

Pagina 33

and delegated using role based security.HP-UX Kernel ConfigurationHP-UX Kernel ConfigurationHP-UX Kernel ConfigurationHP-UX Kernel Configuration-for s

Pagina 34

Superdome ServiceSuperdome ServiceSuperdome ServiceSuperdome ServiceSolutionsSolutionsSolutionsSolutionsSuperdome continues to provide the same positi

Pagina 35

Support for Web Console that provides secure text mode access to the managementprocessorReporting of error events from system firmware.Ability to trig

Pagina 36

System Management HomepageSystem Management HomepageSystem Management HomepageSystem Management Homepage displays critical management information thro

Pagina 37

Ability to trigger the task of PCI OL* from the management processor.NOTE:NOTE:NOTE:NOTE: Online addition/replacement (OLAR) is not supported when run

Pagina 38

General Site PreparationGeneral Site PreparationGeneral Site PreparationGeneral Site PreparationRulesRulesRulesRulesAC Power RequirementsAC Power Requ

Pagina 39

Customer Provided PartCustomer Provided PartCustomer Provided PartCustomer Provided PartPDCA ProductPDCA ProductPDCA ProductPDCA Pro

Pagina 40

Ground Leakage Current (mA)>3.5 mA, with 6 BPSs installedWarning label applied to thePDCA at the AC Mains input Cooling RequirementsCoolin

Pagina 41

HP has entered into an agreement with Liebert to reference sell the DataCool solutionThe HP/Liebert business relationship is managed by the HP Com

Pagina 42

ProductProductProductProductNumber/Number/Number/Number/DescriptionDescriptionDescriptionDescriptionQuantity/Quantity/Quantity/Quantity/Configurat

Pagina 43

Power ProtectionPower ProtectionPower ProtectionPower ProtectionRuntimesRuntimesRuntimesRuntimesThe UPS will provide battery backup to allow for a gra

Pagina 44

DescriptionDescriptionDescriptionDescriptionNetwork interface cards that provide standards-based remote managementof UPSsGeneral FeaturesGeneral F

Pagina 45

Minimum/Maximum Configurations for Superdome (sx1000 & sx2000) with Intel Itanium 2 Processors (1.5 GHz and 1.6 GHz)Minimum/Maximum Configurations

Pagina 46

CategoryCategoryCategoryCategoryRule IndexRule IndexRule IndexRule IndexRule DescriptionRule DescriptionRule DescriptionRule DescriptionGeneralGeneral

Pagina 47

26If a partition contains 4 or fewer cells, all the cells should be linked to the same crossbar (quad)in order to eliminate bottlenecks and the sharin

Pagina 48

Single SystemSingle SystemSingle SystemSingle SystemHigh AvailabilityHigh AvailabilityHigh AvailabilityHigh Availability36Each cell should have at lea

Pagina 49

TraditionalTraditionalTraditionalTraditionalMulti-SystemMulti-SystemMulti-SystemMulti-SystemHigh AvailabilityHigh AvailabilityHigh AvailabilityHigh Av

Pagina 50

* Superdome 32 processor system requires an I/O expansion cabinet for greater than 4 nodes. Superdome 64 processor systemrequires an I/O expansion cab

Pagina 51

For information on Superdome System Upgrades, please refer to the Superdome Server Upgrades QuickSpec.QuickSpecsHP Integrity Superdome Servers 16- pro

Pagina 52

TotalTotalTotalTotalAmountAmountAmountAmountMemoryMemoryMemoryMemoryper Cellper Cellper Cellper CellNo. ofNo. ofNo. ofNo. of512 MB512 MB512 MB512 MBNo

Pagina 53

NOTESNOTESNOTESNOTES:1. Configurations with 8, 16, or 32 DIMMs will result in the best performance2. These are configurations that are shipped from ma

Pagina 54

568242 GB 2 GB 2 GB 2 GB 2 GB 2 GB 2 GB 2 GB 2 GB 2 GB 2 GB 2 GB 1 GB 1 GB 1 GB 1 GB56 24 84 GB 4 GB 4 GB 4 GB 1 GB 1 GB 1 GB 1 GB 1 GB 1 GB 1 GB 1 G

Pagina 55

Superdome sx2000Superdome sx2000Superdome sx2000Superdome sx2000SpecificationsSpecificationsSpecificationsSpecificationsSPU DescriptionSPU Description

Pagina 56

Memory2 GB 2 GB 2 GB 2 GB512 GB/256 GB(sx2000)512 GB(sx1000with DCEdition)/1024 GB(sx2000with DCEdition)/128 GB(sx1000with EE)/256 GB(sx2000with EE)25

Pagina 57

4-GB DIMMs (DDRII)32-512 GB32-1024 GB64-2048 GB (max. is1024 GB for Windows)DIMM Density (MB)1024/2048/4096 1024/2048/4096 1024/2048/4096 Cell BoardsC

Pagina 58

Number of Itanium 2 1.5GHz or 1.6 GHzprocessors2 - 16 2 - 32 6 - 64Windows Server 2003Enterprise Editionsupports a maximum of 8processors per partitio

Pagina 59

1 processor (mx2 only)/2processor 3 processor(mx2 only)/4 processorcells1 - 4 1 - 83 - 16 Software SupportSoftware SupportSoftware SupportSoftware Sup

Pagina 60

Additional InterfaceCards88 -14 8 -14Typical Electrical Characteristics by ConfigurationTypical Electrical Characteristics by ConfigurationTypical Ele

Pagina 61

Environmental CharacteristicsEnvironmental CharacteristicsEnvironmental CharacteristicsEnvironmental CharacteristicsAcoustics65 dBOperating temperatur

Pagina 62

Typical 3 phase 4 wirecurrent requirements at200V 240V17A/Phase 29A/PhaseTwo cabinets 29A/PhaseTypical 3 phase 5 wirecurrent requirements at200V 240V1

Pagina 63

Regulatory ComplianceRegulatory ComplianceRegulatory ComplianceRegulatory ComplianceSafetyIEC 950:1991+A1, +A2, +A3, +A4; EN60950:1992+A1, +A2, +A3,+A

Pagina 64

12 slot PCI X chassis forHP rack expansion cabinetNot ApplicableA6864AZ (sx1000)A9836AZ (sx2000)A6864AZ (sx1000)A9836AZ (sx2000)I/O Expansion CabinetP

Pagina 65

Shipping height66.93 in (170.00 cm) Shipping width43.31 in (110.00 cm) Shipping depth35.43 in(90.00 cm) ColorDark green (NCS 7020 B50G), Light gray (

Pagina 66

Mass Storage Host Bus AdaptersMass Storage Host Bus AdaptersMass Storage Host Bus AdaptersMass Storage Host Bus AdaptersPCI 2x Fibre ChannelA5158ALCH4

Pagina 67

1Requires I/O expansion cabinet if more than 4 nPARS2Requires I/O expansion cabinet if more than 8 nPARS31.6 Ghz Mad9M Processors only on sx1000 c

Pagina 68

PCI-X 4Gb Fiber Channel AdapterFC2143BRAD167AW, L24 24 24Windows: Noboot supportfrom factory;boot supportcapable withcomplete systemintegration in the

Pagina 69

PCI X 1 channel 2 Gb /sFibreChannel WindowsAB467ALCW32 32 32Windows: Noboot supportfrom factory;boot supportcapable withcomplete systemintegration in

Pagina 70

HP PCI-X 2-port 4X Fabric (HA &DB) AdptAB345A4x InfinibandCopperH16 32 64No boot supportHP PCI-X 10 GigEAB287ADuplex LCH8181161PCI-X 10GbE LAN Ada

Pagina 71

PCI 64-port Terminal MultiplexerA6749ARS-232 or RS-422H814 14 1 Maximum cards are two per I/O chassis. Therefore: 16 processor=8 maximum, 32 processor

Pagina 72

PCI-X 4Gb Fiber ChannelAdapter FC2143BRAD167AW24 24 24Windows: Noboot supportfrom factory;boot supportcapable withcomplete systemintegration in thefie

Pagina 73

PCI 1 port 802.5 Token Ring4/16/100A5783ARJ-45 and DB9H816 32 PCI 1 port 1000Base T (gigabitcopper)A6825ARJ-45H, O16 32 64 OpenVMS -8/partPCI 1 port 1

Pagina 74

HP Linux 133MHz 10GbE SRFiber AdapterAD144ADuplex LCL, W48 (W) 8 (W) 8 (W)Windows: Noboot supportfrom factory.Boot supportcapable withcomplete systemi

Pagina 75

Wide Area Network (WAN) AdaptersWide Area Network (WAN) AdaptersWide Area Network (WAN) AdaptersWide Area Network (WAN) AdaptersPCI 1 port ATM 155 Mbp

Pagina 76

The boot configuration for Windows Server 2003, Datacenter Edition Superdome partitions can be:The Smart Array 6402/6404 disk array controllers (A9890

Pagina 77

Superdome Supported Online StorageSuperdome Supported Online StorageSuperdome Supported Online StorageSuperdome Supported Online StorageStorage Device

Pagina 78

Maximum nParsNotapplicableNotapplicableNotapplicableNotapplicable81Datacenter81;Enterprise 2 818164 Processors / 128 Cores64 Processors / 128 Cores64

Pagina 79

SAN 2/8 ELYesNoYes YesSAN 2/16YesNoYes YesSAN 2/16 ELYesNoYes YesStorageWorks Core 2/64Yes Yes Yes YesStorageWorks Edge 2/24YesNoYes YesStorageWorks E

Pagina 80

DVD - RackYes Yes YesNoTA5300 - Tape Array (plus all supporteddevices in TA5300)*Yes Yes Yes YesDDS-4 Standalone/RackYes Yes Yes YesDDS-4×6 Standalone

Pagina 81

© Copyright 2003-2006 Hewlett-Packard Development Company, L.P.The information contained herein is subject to change without notice.Microsoft and Win

Pagina 82

The HP Integrity (sx1000) Superdome servers may require a firmware update to support Intel Itanium 2Processor/Cell Add on products shipping after June