Section 6: Programming Basics 77
R
1
and R
0
allocated for data
storage; R
2
to R
65
available for
programming and advanced
functions.
Original allocation: R
19
(R
.9
) and
below for data storage; R
20
, to
R
65
for programming and
advanced functions.
*
Displays the current highest data
register.
The m and W (memory status) functions are described in detail in
appendix C.
Keep in mind that an error message will result (given the above memory
configuration) if
You try to address a register higher than R
19
(R
.9
), which initially is
the highest register allocated to data storage (Error 3).
You have 322 occupied program bytes and try to load more program
lines (Error 4).
You try to run an advanced function with insufficient available
memory (Error 10).
Program Boundaries
End. Not every program needs to end with a n or ¦ instruction. If
you are at the end of occupied program memory, there is an automatic
n instruction, so you do not need to enter one. This can save you one
transferring execution to another routine using t (section 7).
Labels. Labels in a program (or subroutine) are markers telling the
calculator where to begin execution. Following an ´ label or G label
instruction, the calculator will search downward in program memory for the
*
For memory allocation and indirect addressing, registers R
.0
through R
.9
are referred to as R
10
through R
19
.