HP 37718A Manuale Utente Pagina 78

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 190
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 77
68
Making Measurements
Using Overhead BER Test Function
Using Overhead BER Test Function
Description You can perform a Bit Error Rate test on chosen bytes of the section, line
and path overhead bytes.
You can access the transmit Overhead BER on the
display.
HOW TO: 1 Set up the SONET transmit interface and payload required. See
"Setting SONET Transmit Interface " page 4.
2 Set up the receive SONET interface and payload as required. See
"Setting SONET Receive Interface " page 17.
3 Choose the overhead byte to be tested on the
display.
4 Choose the overhead byte to be tested on the
display.
5 Press to start the test.
6 The PRBS pattern can be errored by pressing .
TRANSMIT
SONET
TEST FUNCTION
RECEIVE
SONET
TEST FUNCTION
TRANSMIT
SONET
TEST FUNCTION
RUN/STOP
SINGLE
Vedere la pagina 77