HP StorageWorksMPxIO for Sun Solarisapplication notesPart number: AA-RW7CE-TEThird edition: December 2006
Verify the MPxIOconfigurationAfter the system has rebooted, use the format or luxadm com mand to verify tha t the MPxIOenablement has been successful.N
Class primaryState ONLINEController /devices/pci@1f,4000/lpfc@5/fp@0,0Device Address 50001fe1002709f9,2Host controller port WWN 10000000c93d5ceeClass
Legal and notice information© Copyright 2005-2006 Hewlett-Packard Development Company, L.P.Hewlett-Packard Company makes no warranty of any kind with
About this documentThis section desc ribes the f ollowing topics:• Applicationnotes information• Intended audience• Other do cumentationApplication no
NOTE:MPxIO is not supported on versions of the EVA3000/5000 prior to 4.004.Supported hardware and softwareTable 1 describes suppor ted hardware and so
Supported multipathing combinationsThe combinationofMPxIOandSecurePathonthesameservercanonlybesupportedifFCA2257Pisused for Secure Path and Sun native
Confi gure and verify the hostVerifying configuration settingsVerify that all paths to the storage system are p resent with cfgadm -al command. To displ
NOTE:Using the option –o show_FCP_dev could result in the output of the cfgadm command todisplay the Type array-ctrl as unconfigured. This is not a pro
5. For all Solaris releases on SPARC, check the multi-pathing information for all LUN s (first example)and either for a given disk/LUN or for the array
May 18 15:10:30 simonb Create devinfo failed.Enabling MPxIOTo enable MPxIOfor HP storage devices, the appropriate information for device-type-scsi-opt