22 HP MSA 500 G2 Storage System Maintenance and Service Guide
8. Remove the interconnect blanks ("Interconnect Blank" on page 20).
9. Remove the power button/LED assembly ("Power Button/LED Assembly"
on page 20
).
10. Handwrite the serial number of the original chassis on the label of the
replacement chassis.
IMPORTANT: Always keep the serial number of the original chassis for
warranty validation purposes. After chassis replacement, HP SIM only
recognizes the new serial number.
11. Install all removed components in the new chassis. To replace each
component, refer to the procedures in this section.