QuickSpecs
HP Integrity Superdome Servers: 16-way, 32-way,
HP Integrity Superdome Servers: 16-way, 32-way,HP Integrity Superdome Servers: 16-way, 32-way,
HP Integrity Superdome Servers: 16-way, 32-way,
and 64-way
and 64-wayand 64-way
and 64-way
Overview
DA - 11717 Worldwide — Version 1 — June 30, 2003
Page 1
Vedere la pagina 0
1 2 3 4 5 6 ... 38 39

Sommario

Pagina 1

QuickSpecsHP Integrity Superdome Servers: 16-way, 32-way,HP Integrity Superdome Servers: 16-way, 32-way,HP Integrity Superdome Servers: 16-w

Pagina 2

HP-UX: Serviceguard and Serviceguard Extension for RACWindows Server 2003: Microsoft Cluster Service (MSCS) - limited configurations supportedLinux: S

Pagina 3

access to the MP, and by its support for multiple geographically distributed console devices.Three common data center styles are:The secure site where

Pagina 4

WindowsWindowsWindowsWindowsTFor Windows Server 2003 customers desiring full visibility to the Superdome Windows partition, an IP console solution isa

Pagina 5

Functional Capabilities:Functional Capabilities:Functional Capabilities:Functional Capabilities:Allows local access to SMS by CE.Provides integrated c

Pagina 6

and security, and handle disk and file system management and peripheral device management. ServicecontrolManager enables these tasks to be distributed

Pagina 7

All other OpenView management tools, such as OpenView Operations, Service Desk, and Service Reporter, will be able tocollect and process information f

Pagina 8

Itanium2 based workstation or server running HP-UX 11i Version 2) in order to configure Linux partitions. Refer toHP-UX section above for key features

Pagina 9

Customer Provided PartCustomer Provided PartCustomer Provided PartCustomer Provided PartPDCA ProductPDCA ProductPDCA ProductPDCA Pro

Pagina 10 - QuickSpecs

alternative cooling solutions may need to be explored by the customer. HP has teamed with Liebert to develop aninnovative data room cooling solution c

Pagina 11

For more information on the product and to manage the reference sales process. Please go tohttp://hpcp.grenoble.hp.com/ for more information.

Pagina 12

At A GlanceAt A GlanceAt A GlanceAt A GlanceThe latest release of Superdome, HP Integrity Superdome supports the new and improved sx1000 chip set. HP

Pagina 13

The APC SL20KFB2 provides unparalleled power conditioning with its Delta-Conversion on- line double conversiontechnology. This is especially helpful i

Pagina 14

Ordering GuidelinesOrdering GuidelinesOrdering GuidelinesOrdering Guidelines The APC SL20KFB2 Silcon 3-phase UPS units may be ordered as p

Pagina 15

16161616Removable media device controller should be in slot 8 of the I/O chassis.Removable media device controller should be in slot 8 of the I/O chas

Pagina 16

33333333Same amount of memory in each cell, but non optimal and/or mixed loading within a cellSame amount of memory in each cell, but non optimal and/

Pagina 17

8800 128 way systems). This requirement is due to a possible 50% cluster failure.8800 128 way systems). This requirement is due to a possible 50% clus

Pagina 18

Superdome server will be populated with two or four CPUs and the customer orders the number of CPUs that must beactivated prior to shipment. D

Pagina 19

Red Hat Enterprise Linux AS 3 and Debian LinuxRed Hat Enterprise Linux AS 3 and Debian LinuxRed Hat Enterprise Linux AS 3 and Debian LinuxRed Hat Ente

Pagina 20

This section applies to upgrades within HP Integrity Superdome systems. For information on upgrades from existing HP 9000 Superdome systems to HPInteg

Pagina 21

Card (A5210A) must be ordered whenordering a Superdome 32-way to 64-way upgrade. Add-on Upgrade RequirementsAdd-on Upgrade RequirementsAdd-on Upgrade

Pagina 22

Benefits of Optional ServicesBenefits of Optional ServicesBenefits of Optional ServicesBenefits of Optional ServicesOptional ServiceOptional ServiceOp

Pagina 23

Superdome ServiceSuperdome ServiceSuperdome ServiceSuperdome ServiceSolutionsSolutionsSolutionsSolutionsSuperdome continues to provide the same positi

Pagina 24

iCOD for Add-on andiCOD for Add-on andiCOD for Add-on andiCOD for Add-on andUpgradesUpgradesUpgradesUpgradesThe customer's current system configu

Pagina 25

TotalTotalTotalTotalAmountAmountAmountAmountMemoryMemoryMemoryMemoryper Cellper Cellper Cellper CellNo. ofNo. ofNo. ofNo. of512 MB512 MB512 MB512 MBNo

Pagina 26

Superdome SpecificationsSuperdome SpecificationsSuperdome SpecificationsSuperdome SpecificationsSPU Model NumberSPU Model NumberSPU Model NumberSPU Mo

Pagina 27

3-phase 5-wire input Option 6:3-phase 4-wire input44 A 44 A 44 A Required Power Receptacle-Options 6 and 7None. Cord, plug and included. Receptacle sh

Pagina 28

Superdome I/O ExpansionSuperdome I/O ExpansionSuperdome I/O ExpansionSuperdome I/O Expansion(IOX) Cabinet(IOX) Cabinet(IOX) Cabinet(IOX) CabinetSpecif

Pagina 29

G84Y) Units per Pallet1.0 Communications andCommunications andCommunications andCommunications andManagementManagementManagementManagementInterface

Pagina 30

Superdome Supported I/OSuperdome Supported I/OSuperdome Supported I/OSuperdome Supported I/OCardCardCardCardProduct #Product #Product #Product #HP-UX

Pagina 31

Superdome Supported Online StorageSuperdome Supported Online StorageSuperdome Supported Online StorageSuperdome Supported Online StorageStorage Device

Pagina 32

Superdome Supported Nearline StorageSuperdome Supported Nearline StorageSuperdome Supported Nearline StorageSuperdome Supported Nearline StorageStorag

Pagina 33

© Copyright 2003 Hewlett-Packard Development Company, L.P.The information contained herein is subject to change without notice.Microsoft and Windows S

Pagina 34

SystemSystemSystemSystemHP UX 11i version 2HP UX 11i version 2HP UX 11i version 2HP UX 11i version 2Windows Server 2003 DatacenterWindows Server 2003

Pagina 35

There are three basic building blocks in the Superdome system architecture: the cell, the crossbar backplane and the PCI X based I/O subsystem.Cabinet

Pagina 36

I/O SubsystemI/O SubsystemI/O SubsystemI/O SubsystemEach I/O chassis provides twelve PCI X slots; eight standard and four high bandwidth PCI X slots.

Pagina 37

I/O Expansion CabinetI/O Expansion CabinetI/O Expansion CabinetI/O Expansion CabinetThe I/O expansion functionality is physically partitioned into fou

Pagina 38

DVD SolutionDVD SolutionDVD SolutionDVD SolutionThe DVD solution for Superdome requires the following components. These components are recommended per

Pagina 39

CPUCPUCPUCPU: The features below nearly eliminate the down time associated with CPU cache errors (which are the majorityof CPU errors). If a CPU is ex