Hardware options installation 96
Installing the 6 bay LFF drive backplane expander
1. Do one of the following:
o For tower models, open and remove the bezel ("Remove the tower bezel" on page 21).
o For rack models, if installed, remove the security bezel (on page 21).
2. Power down the server (on page 20).
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. For tower models, do the following:
a. Place the server on a flat, level surface with the access panel facing up.
b. Remove the access panel (on page 23).
5. For rack models, do the following:
a. Extend the server from the rack (on page 24).
b. Remove the access panel (on page 23).
c. Release thumbscrews and remove the rack bezel.
6. Remove the existing component cage cover for the LFF drive cage.