Hardware options installation 45
18.
Route the fan cable through the cable slot.
19. Connect the fan cable to the system board, and then insert the fan.
20. Install the system air baffle (on page 28).
21. If removed, install the PCI air baffle ("PCI air baffle option" on page 38).
22. Install the access panel (on page 26).
23. Return the server to an upright position.
24. Lock the front bezel (on page 24).
25. Connect each power cord to the server.
26. Connect each power cord to the power source.
27. Power up the server (on page 23).
Memory options
IMPORTANT: This server does not support mixing LRDIMMs, RDIMMs, or UDIMMs. Attempting
to mix any combination of these DIMMs can cause the server to halt during BIOS initialization.
The memory subsystem in this server can support RDIMMs or UDIMMs: