Hp StorageWorks X3000 Network Storage Systems Manuale Utente

Navigare online o scaricare Manuale Utente per Magazzini Hp StorageWorks X3000 Network Storage Systems. HP StorageWorks X3000 Network Storage Systems User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 130
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti

Sommario

Pagina 1 - HP StorageWorks

HP StorageWorksX1000 and X3000 Network Storage Systemuser guidePart number: 5697-0185First edition: November 2009

Pagina 2

Storage system cluster diagram ... 8832Cluster concepts diagram ...

Pagina 3 - Contents

2. For NFS environments, configure the NFS server.NFS specific procedures include entering audit and file lock information as well as setting upclient

Pagina 4

Example: If the password and group files are located at c:\maps on node 1, then they must alsobe at c:\maps on node 2. The contents of the password an

Pagina 5

NOTE:• A file share resource must reside in the same cluster group as the physical disk resource it willreside on.• The physical disk resource specifi

Pagina 6

• Configuring User Name Mapping on a server clusterFor further details, see the online help for Microsoft Services for Network File System.Best practi

Pagina 7

6. To add a printer to the virtual server:a. Double-click the printers and faxes icon.b. Right-click the new screen, and then click add printer. A wiz

Pagina 8

Restarting one cluster nodeCAUTION:Restarting a cluster node should be done only after confirming that the other node(s) in the clusterare functioning

Pagina 9

Powering up the clusterThe power up process for the storage system cluster is more complex than it is for a single nodebecause extra care must be take

Pagina 10

7 Troubleshooting, servicing, andmaintenanceTroubleshooting the storage systemThe “Support and troubleshooting” task at the HP Support & Drivers w

Pagina 11

• CCAT (Computer Crash Analysis Tool)• SEA (System Event Analyzer)If you have a warranty or service contract with HP you are entitled to these tools f

Pagina 12

8 System recoveryThis chapter describes how to use the System Recovery DVD that is provided with your storage system.The System Recovery DVDThe HP Sto

Pagina 13 - About this guide

TablesDocument conventions ... 131HP Rapid Startup Wizard co

Pagina 14 - Rack stability

6. Click Yes to continue. If the old drive letter needs to be re-used, reboot the server after clickingYes.System recovery110

Pagina 15 - HP websites

A Regulatory compliance noticesThis section contains regulatory notices for the HP StorageWorks family of products.Regulatory compliance identificatio

Pagina 16 - Documentation feedback

of this equipment in a residential area is likely to cause harmful interference, in which case the userwill be required to correct the interference at

Pagina 17 - Check kit contents

Class B equipmentThis Class B digital apparatus meets all requirements of the Canadian Interference-Causing EquipmentRegulations.Cet appareil numériqu

Pagina 18 - Access the storage system

Korean noticesClass A equipmentClass B equipmentTaiwanese noticesBSMI Class A noticeTaiwan battery recycle statementRecovery text:• “Please recycle wa

Pagina 19

Laser compliance noticesEnglish laser noticeThis device may contain a laser that is classified as a Class 1 Laser Product in accordance with U.S.FDA r

Pagina 20 - Startup Wizard

French laser noticeGerman laser noticeItalian laser noticeRegulatory compliance notices116

Pagina 21 - Complete system configuration

Japanese laser noticeSpanish laser noticeRecycling noticesEnglish noticeX1000 and X3000 Network Storage System 117

Pagina 22 - Additional access methods

Bulgarian noticeCzech noticeDanish noticeDutch noticeRegulatory compliance notices118

Pagina 23 - Default storage settings

Estonian noticeFinnish noticeFrench noticeGerman noticeX1000 and X3000 Network Storage System 119

Pagina 25 - Default boot sequence

Greek noticeHungarian noticeItalian noticeLatvian noticeRegulatory compliance notices120

Pagina 26

Lithuanian noticePolish noticePortuguese noticeRomanian noticeX1000 and X3000 Network Storage System 121

Pagina 27

Slovak noticeSpanish noticeSwedish noticeTurkish noticeTürkiye Cumhuriyeti: EEE Yönetmeli ine UygundurRegulatory compliance notices122

Pagina 28 - StatusItem / Description

Battery replacement noticesDutch battery noticeX1000 and X3000 Network Storage System 123

Pagina 29

French battery noticeGerman battery noticeRegulatory compliance notices124

Pagina 30

Italian battery noticeJapanese battery noticeX1000 and X3000 Network Storage System 125

Pagina 31

Spanish battery noticeRegulatory compliance notices126

Pagina 32

IndexAaccess rights, managing, 100Accessing the storage systemRemote Desktop method,Accessing the storage systemremote browser method, 22ACL, defining

Pagina 33

Declaration of Conformity,default storage settings,disk access, verifying, 97Disk Managementextending volumes, 61documentconventions, 13related docume

Pagina 34 - 1. PCIe slot 5

Oonline spares, 50Ppartitionsextended, 51primary, 51permissionsfile level, 76listadding users and groups,removing users and groups,modifying, 78resett

Pagina 35

About this guideThis guide provides information about installing, configuring, managing, and troubleshooting thefollowing HP StorageWorks Network Stor

Pagina 36 - SAS and SATA hard drive LEDs

sharesadministrative, 84managing, 82standard, 84Single Instance Storage,storage configurations, 23storage managementelements, 47overview, 47process, 4

Pagina 37 - Systems Insight Display LEDs

ElementConvention• File and directory names• System output• Code• Commands, their arguments, and argument valuesMonospace text• Code variables• Comma

Pagina 38

WARNING!To reduce the risk of personal injury or damage to equipment:• Extend leveling jacks to the floor.• Ensure that the full weight of the rack re

Pagina 39

•http://www.hp.com/go/storage•http://www.hp.com/service_locator•http://www.hp.com/support/manuals•http://www.hp.com/support/downloadsDocumentation fee

Pagina 40 - Display LED and

1 Installing and configuring the serverSetup overviewThe HP StorageWorks X1000 Network Storage System comes preinstalled with the MicrosoftWindows® St

Pagina 41 - 3 Administration tools

• Power cord(s)• Product Documentation and Safety and Disposal Documentation CD• HP StorageWorks Storage System Recovery DVD• End User License Agreeme

Pagina 42 - Share and Storage Management

NOTE:• The keyboard, mouse, and monitor are not provided with the storage system.• The X1600 does not include PS/2 ports for connecting a keyboard and

Pagina 43 - Configuring ADLDS

Legal and notice information© Copyright 1999, 2009 Hewlett-Packard Development Company, L.P.Confidential computer software. Valid license from HP requ

Pagina 44 - Single Instance Storage

4. Re-type the Administrator password in the Confirm password box.5. Click the blue arrow next to the Confirm password box.6. Click OK.After the Admin

Pagina 45 - Print Management

Figure 1 HP StorageWorks Rapid Startup Wizard Welcome screen.For detailed information about each of these configuration options, click the correspondi

Pagina 46 - Administration tools46

• Installing third-party software applications—For example, these might include an antivirus applic-ation that you install.• Registering the server —

Pagina 47 - 4 Storage management overview

Using the Remote Desktop methodRemote Desktop provides the ability for you to log onto and remotely administer your server, givingyou a method of mana

Pagina 48 - Physical storage elements

The Operating System volume default factory settings can be customized after the operating systemis up and running. The following settings can be chan

Pagina 49

NOTE:In the HP Array Configuration Utility (ACU), logical disks are labeled 1 and 2. In Microsoft DiskManager, logical disks are displayed as 0 and 1.

Pagina 50 - Logical storage elements

Installing and configuring the server26

Pagina 51 - Partitions

2 Storage system component identificationThis chapter provides illustrations of the storage system hardware components.NOTE:The keyboard, mouse, and m

Pagina 52 - File sharing elements

Figure 3 HP X1400 and X3400 front panel LEDs.Table 4 HP X1400 and X3400 front panel LED descriptionsStatusItem / DescriptionGreen = System health is n

Pagina 53 - Management tools

1. Power cord connector2. Mouse connector3. 10/100/1000 NIC 1 connector/shared iLO 2 management port4. 10/100/1000 NIC 2 connector5. Serial connector6

Pagina 54 - Management Agents

ContentsAbout this guide ... 13Intended audience ...

Pagina 55 - 5 File server management

Figure 6 HP X1600 front panel components and LEDs.Table 6 HP X1600 front panel component and LED descriptionsStatusItem / DescriptionSee “SAS and SATA

Pagina 56 - File services management

Figure 7 HP X1600 rear panel components.1. Redundant hot-plug power supplies2. Power supply cable socket3. Rear DVD-RW drive4. x8 full-length /full-he

Pagina 57 - Array Configuration Utility

Figure 8 HP X1600 (AW528A) rear panel components.The HP X1600 Network Storage System AW528A model includes two 2.5” Small Form Factor (SFF)SAS / SATA

Pagina 58 - Disk Management utility

Figure 9 HP X1800 and X3800 front panel components.1. Quick release levers (2)2. Systems Insight DisplayNOTE:See “Systems Insight Display LEDs” on pag

Pagina 59 - Disk quotas

Figure 10 HP X1800 and X3800 front panel LEDs and buttons.Table 7 HP X1800 and X3800 front panel LED and button descriptionsStatusItem / DescriptionBl

Pagina 60 - Adding storage

2. PCIe slot 63. PCIe slot 44. PCIe slot 25. PCIe slot 36. PCIe slot 1 (occupied by Smart Array controller with external SAS ports for expandability)7

Pagina 61

StatusItem / DescriptionGreen = Network activityFlashing green = Network activityOff = No network activity3. NIC/iLO 2 activity LEDGreen = Network lin

Pagina 62 - Volume shadow copies

Status2. Online/activity LED(green)1. Fault/UID LED (am-ber/blue)Do not remove the drive. Removing a drive mayterminate the current operation and caus

Pagina 63 - Allocating disk space

Figure 14 Systems Insight Display LEDs.Table 10 Systems Insight Display LED descriptionsStatusItem / DescriptionGreen = Network linkFlashing green = N

Pagina 64 - Identifying the storage area

Systems Insight Display LED combinationsWhen the internal health LED on the front panel illuminates either amber or red, the server isexperiencing a h

Pagina 65 - Managing shadow copies

Share and Storage Management ... 42Microsoft Services for Netwo

Pagina 66 - The shadow copy cache file

StatusInternal health LEDcolorSystems InsightDisplay LED andcolorThe Health Driver has detected a cautionary temperature level.AmberOvertemperature(am

Pagina 67

3 Administration toolsHP StorageWorks X1000 and X3000 Network Storage Systems include several administration toolsto simplify storage system managemen

Pagina 68 - Set schedules

Remote Desktop for Administration does not require the purchase of special licenses for client computersthat access the server. It is not necessary to

Pagina 69 - Disabling shadow copies

Mapping Setup Wizard. After completing the initial Microsoft Services for NFS configuration, youcan use the Microsoft Services for NFS console for ong

Pagina 70 - File server management70

Script executionYou can configure ADLDS by executing the nfs-adam-config.js script that is located in thec:\hpnas\components\ADLDS directory. Executin

Pagina 71 - SMB shadow copies

• Groveler service - The Groveler service scans the hard-disk volumes on a server for duplicatecopies of files. If the service locates duplicate copie

Pagina 72 - NFS shadow copies

Administration tools46

Pagina 73 - Recovery of files or folders

4 Storage management overviewThis chapter provides an overview of some of the components that make up the storage structure ofthe storage system.Stora

Pagina 74 - Recovering a folder

Figure 15 Storage management process example.Physical storage elementsThe lowest level of storage management occurs at the physical drive level. Minim

Pagina 75 - Folder and share management

• Include the appropriate number of physical drives in the arrays to create logical storage elementsof desired sizes.ArraysSee Figure 16. With an arra

Pagina 76 - Folder management

Shadow copies and drive defragmentation ... 65Mounted drives ...

Pagina 77

Fault toleranceDrive failure, although rare, is potentially catastrophic. For example, using simple striping as shownin Figure 17, failure of any hard

Pagina 78 - File server management78

It is important to note that a LUN may span all physical drives within a storage controller subsystem,but cannot span multiple storage controller subs

Pagina 79

dynamic disks is unavailable. There could be a potential for data loss depending on the nature of thefailed LUN.Volumes are created out of the dynamic

Pagina 80 - File server management80

Shadow copies should not replace the current backup, archive, or business recovery system, but theycan help to simplify restore procedures. For exampl

Pagina 81

For additional information, refer to the Management CD in the HP ProLiant Essentials Foundation Packor the HP SIM website (http://www.hp.com/go/hpsim)

Pagina 82 - Share management

5 File server managementThis chapter begins by identifying file services in Windows Storage Server 2008. The remainder ofthe chapter describes the man

Pagina 83 - Defining Access Control Lists

File services managementInformation about the storage system in a SAN environment is provided in the HP StorageWorks SANManuals page located on the HP

Pagina 84 - File Server Resource Manager

Array management utilitiesStorage devices for RAID arrays and LUNs are created and managed using the array managementutilities mentioned previously. F

Pagina 85 - Storage reports

• Extending and expanding arrays and logical drives is supported.The HP Array Configuration Utility User Guide is available for download at http://www

Pagina 86 - Antivirus

Scheduling defragmentationDefragmentation is the process of analyzing local volumes and consolidating fragmented files andfolders so that each occupie

Pagina 87 - 6 Cluster administration

Preparing for cluster installation ... 94Before beginni

Pagina 88 - Cluster terms and components

per-user basis. It is also possible to specify whether or not to log an event when users exceed eithertheir quota warning level or their quota limit.W

Pagina 89 - Quorum disk

Extending storage using Windows Storage UtilitiesVolume extension grows the storage space of a logical drive. During this process, the administratorad

Pagina 90 - Cluster concepts

Expand logical driveThis option in the ACU increases the storage capacity of a logical drive by adding unused space onan array to the logical drive on

Pagina 91 - Cluster planning

• How frequently will shadow copies be made?Identifying the volumeShadow copies are taken for a complete volume, but not for a specific directory. Sha

Pagina 92 - Network planning

NOTE:Regardless of the volume space that is allocated for shadow copies, there is a maximum of 64 shadowcopies for any volume. When the 65th shadow co

Pagina 93 - Protocol planning

Shadow copies and drive defragmentationWhen running Disk Defragmenter on a volume with shadow copies activated, all or some of theshadow copies may be

Pagina 94 - Before beginning installation

Figure 19 System administrator view of Shadow Copies for Shared Folders.The shadow copy cache fileThe default shadow copy settings allocate 10 percent

Pagina 95 - Cluster installation

Figure 21 Shadow copies stored on a separate volume.The main advantage to storing shadow copies on a separate volume is ease of management andperforma

Pagina 96 - Setting up networks

NOTE:After the first shadow copy is created, it cannot be relocated. Relocate the cache file by altering thecache file location under Properties prior

Pagina 97 - Creating a cluster

CAUTION:Use caution when reducing the size limit for all shadow copies. When the size is set to less than thetotal size currently used for all shadow

Pagina 98 - Cluster group overview

Firmware updates ... 108Certificate of Authe

Pagina 99 - Resource planning

Managing shadow copies from the storage system desktopTo access shadow copies from the storage system desktop:The storage system desktop can be access

Pagina 100 - NFS cluster-specific issues

NOTE:Shadow Copies for Shared Folders clients are not available for HTTP, FTP, AppleTalk, or NetWareshares. Consequently, users of these protocols can

Pagina 101 - Creating file share resources

Figure 23 Client GUI.When users view a network folder hosted on the storage system for which shadow copies are enabled,old versions (prior to the snap

Pagina 102 - Extend a LUN in a cluster

[email protected]:00:00Access to NFS shadow copy pseudo-subdirectories is governed by normal access-control mechanismsusing the permissions stored i

Pagina 103 - Print services in a cluster

Figure 24 Recovering a deleted file or folder.Recovering an overwritten or corrupted fileRecovering an overwritten or corrupted file is easier than re

Pagina 104 - Failing over and failing back

Backup and shadow copiesShadow copies are only available on the network via the client application, and only at a file orfolder level as opposed to th

Pagina 105 - Powering down the cluster

NOTE:Select servers can be deployed in a clustered or non-clustered configuration. This section discussesshare setup for a non-clustered deployment.Fo

Pagina 106 - Powering up the cluster

2. Click Properties, and then click the Security tab.Figure 25 Properties dialog box, Security tab.Several options are available on the Security tab:•

Pagina 107

3. To modify ownership of files, or to modify individual file access level permissions, click Advanced.Figure 26 illustrates the properties available

Pagina 108 - Certificate of Authenticity

4. Enable or disable permissions by selecting the Allow box to enable permission or the Deny boxto disable permission. If neither box is selected, per

Pagina 109 - 8 System recovery

Polish notice ... 121Portuguese notic

Pagina 110 - System recovery110

Figure 28 Advanced Security Settings dialog box, Auditing tab.5. Click Add to display the Select User or Group dialog box.Figure 29 Select User or Gro

Pagina 111 - FCC rating label

7. Click OK.The Auditing Entry dialog box is displayed.Figure 30 Auditing Entry dialog box for folder name NTFS Test.8. Select the desired Successful

Pagina 112 - Class A equipment

Figure 31 Advanced Security Settings dialog box, Owner tab.The current owner of the file or folder is listed at the top of the screen. To take ownersh

Pagina 113 - Japanese notices

The content of shares should be carefully chosen to avoid two common pitfalls: either having too manyshares of a very specific nature, or of having ve

Pagina 114 - Taiwanese notices

• Standard shares are shares that do not end in a $ character. Standard shares are listed whenevera CIFS client browses for available shares on a CIFS

Pagina 115 - Laser compliance notices

File screening managementOn the File Screening Management node of the File Server Resource Manager snap-in, you canperform the following tasks:• Creat

Pagina 116 - Italian laser notice

For more information, and to download the utility, see the StorageWorks L&TT web site at http://h18006.www1.hp.com/products/storageworks/ltt.Antiv

Pagina 117 - Recycling notices

6 Cluster administrationHP StorageWorks X3000 Network Storage Systems support clustering; HP StorageWorks X1000Network Storage Systems do not.One impo

Pagina 118 - Dutch notice

Figure 32 Storage system cluster diagram.Cluster terms and componentsNodesThe most basic parts of a cluster are the servers, referred to as nodes. A s

Pagina 119 - German notice

• CIFS file share resources• NFS file share resources• FTP file share resources• iSCSI resourcesCluster groupsCluster resources are placed together in

Pagina 120 - Latvian notice

FiguresHP StorageWorks Rapid Startup Wizard Welcome screen ... 211HP X1400 and X3400 front panel components .

Pagina 121 - Romanian notice

• Storing the most current version of the cluster database• Guaranteeing that only one set of active communicating nodes is allowed to operate as a cl

Pagina 122 - Turkish notice

3. Physical Disk resources are created for each basic disk inside Cluster Administrator.4. Directories and folders are created on assigned drives.5. C

Pagina 123 - Battery replacement notices

• Storage planning• Network planning• Protocol planningStorage planningFor clustering, a basic disk must be designated for the cluster and configured

Pagina 124 - German battery notice

• The private cluster interconnect or “heartbeat” crossover cable connects to one of the networkports on each cluster node. In more than two node depl

Pagina 125 - Japanese battery notice

NOTE:AppleTalk is not supported on clustered disk resources. AppleTalk requires local memory for volumeindexing. On failover events, the memory map is

Pagina 126 - Spanish battery notice

Shared disk requirementsNOTE:Do not allow more than one node access the shared storage devices at the same time until Clusterservice is installed on a

Pagina 127

Setting up networksVerify that all network connections are correct, with private network adapters connected to otherprivate network adapters only, and

Pagina 128 - Index128

• Dedicate a separate disk resource for a Quorum disk. Because the failure of the Quorum diskwould cause the entire cluster to fail, HP strongly recom

Pagina 129

• Use of DHCP addresses for network connections. All Network adapters must be configured withstatic IP addresses in a cluster configuration.• File Ser

Pagina 130 - Index130

When creating groups, the administrator's first priority is to gain an understanding of how to managethe groups and their resources. Administrato

Commenti su questo manuale

Nessun commento